Attic Insulation Calculator
Choose your climate zone and what's in the attic now to see the R-value to aim for, how deep the new insulation needs to be — blown-in or batts — and how many bags or packages to buy.
Enter the attic floor area.
On this page
How to use the insulation calculator
- Measure the attic floor — usually the footprint of the heated part of the house below it.
- Choose your climate zone. The labels are a rough guide; the U.S. Department of Energy publishes a county-level climate zone map.
- Tell it what's there now. Measure the depth of the existing insulation. If it's about 3–4 inches, choose that option; otherwise enter its R-value (depth × R per inch for its type).
- Pick the insulation you'll add and, for bags, enter the coverage from the bag's chart at your target R-value.
Recommended attic R-values (ENERGY STAR)
| Climate zone | Uninsulated attic | Attic with 3–4 in existing |
|---|---|---|
| 1 | R-30 | add R-25 |
| 2–3 | R-49 | add R-38 |
| 4–8 | R-60 | add R-49 |
ENERGY STAR recommendations for retrofitting existing wood-framed homes.
R-value per inch
| Material | R per inch (DOE range) | Inches for R-38 | Inches for R-49 |
|---|---|---|---|
| Loose-fill fiberglass | 2.2–2.7 | 14–17 | 18–22 |
| Loose-fill cellulose | 3.2–3.8 | 10–12 | 13–15 |
| Fiberglass batts | 2.9–3.8 | 10–13 | 13–17 |
The calculator uses the middle of each range (2.5, 3.5 and 3.3). Blown-in products list the exact installed thickness and bag count for each R-value on the bag — follow that chart when you install.
Worked example: a 1,200 sq ft attic in zone 5 with 3–4 inches today
- ENERGY STAR recommends adding R-49
- With blown-in fiberglass at R-2.5 per inch: 49 ÷ 2.5 = 19.6 inches on top of what's there
- With cellulose at R-3.5 per inch: 14 inches
Before you add insulation
- Seal air leaks first — around chimneys, plumbing and wiring holes, recessed lights and the attic hatch. Air leaks can undo much of the benefit.
- Keep ventilation open: install baffles at the eaves so insulation doesn't block soffit vents.
- Mind clearances around chimneys, flues and recessed lights that aren't rated for insulation contact.
- Deal with moisture — wet or moldy insulation points to a roof leak or ventilation problem that needs fixing first.
Frequently asked questions
How many inches of insulation is R-49?
Roughly 18 to 22 inches of blown-in fiberglass, 13 to 15 inches of cellulose, or 13 to 17 inches of fiberglass batts.
Can I put new insulation on top of old?
Usually yes, if the old insulation is dry and free of mold or pests. Don't put faced batts (with a vapor retarder) on top of existing insulation — use unfaced batts or loose fill.
How many bags of blown-in insulation do I need?
Divide your attic area by the coverage per bag listed on the bag's chart for your target R-value. Coverage per bag drops as the target R-value rises.
Sources
- ENERGY STAR, Recommended home insulation R-values — attic recommendations by climate zone.
- U.S. Department of Energy, Insulation materials — R-value per inch ranges.